1. A hermetically sealed refrigerator is manufactured and charged at the factory with 4.5 pounds of refrigerant. Under Section 608, how is it classified?

2. Which person meets the regulatory definition of a technician?

3. While servicing an appliance, a technician deliberately releases refrigerant to the atmosphere. This is:

4. How long must records required by the recordkeeping section be retained, unless stated otherwise?

5. Servicing records documenting date, type of service and quantity of refrigerant added are required for appliances normally containing at least:

6. A technician who only services household refrigerators and window air conditioners needs which certification?

7. Certification as a Type II technician is required to service which appliances?

8. A technician servicing a low-pressure centrifugal chiller must hold which certification?

9. To service MVAC-like appliances, such as air conditioning on a construction vehicle, a technician must:

10. Using recovery equipment manufactured before November 15, 1993, what percentage of refrigerant must be recovered from a small appliance?

11. As an alternative to meeting a recovery percentage on a small appliance, the technician may:

12. When recovering refrigerant from an MVAC for disposal, system pressure must be reduced to or below:

13. The leak rate threshold that triggers repair requirements for commercial refrigeration equipment is:

14. Industrial process refrigeration equipment has a leak rate threshold of:

15. A 60-pound rooftop unit provides comfort cooling for an office. What annual leak rate obligates the owner to act?

16. An appliance containing 50 pounds or more that leaks what portion of its full charge in a calendar year triggers a report to EPA?

17. Purged refrigerant may be excluded from annual leak rate calculations when it is destroyed at a verifiable destruction efficiency of at least:

18. Equipment that can remove refrigerant from an appliance without relying on components inside that appliance is called:

19. A Universal certification test consists of: